A complete high-cell alternating pressure system with 20 modular air cells made of high-quality polyurethane (PU)
3 static cells in the head area
Improved and pleasant micro climate through nine laser-perforated cells (ventilation bladders)
21 cm (about 8.27") high air chambers with the Cell-in-Cell-System®: static cells within the alternating pressure air chambers ensure an optimum of pressure distribution and prevention against pressure sores for even the heaviest of patients and for special bedding needs (for example upper body elevation).
Micro chip control ("MCS) electronically monitors the cell pressure and ensures a more economic use of the pump through progressive pressure management
Integrated static function for adjustable soft bedding
Static firm bedding to facilitate basic care and mobilization
Anti-allergenic cover made of Soft-Care-Tex™: breathable and liquid-proof, frictional and gravitational forces are minimized, high comfort through the cover's very soft and pleasant properties
Zipper along the cover's complete circumference may be opened from both sides to ensure the cover's correct position and protect against contamination of the air chambers
The SLK III® complete substitution system may be secured to the bed frame using eight fastening straps, the frame is additionally furnished with a special "anti-slip pad"
CPR-flap for simple and quick deflation for reanimation
Virtually soundless and vibration-free operation of the control unit with a special high-performance pump in "on demand" Technology
Air supply tubes and motor securely attached with special connectors
Bend-proof air supply tubes with safety coating
The motor may be securely affixed to any bed frame up to 11 cm (about 4.3") thick, using plastic-coated metal support brackets
Simple adjustment to patients' respective weights from 40 to 195 kg (88 – 430 lbs.) by turning a dial
Operational mode displayed through colored illuminating diodes
Optical alarm when pressure is too low
The patient's contact surface with the bed is greatly enlarged, therefore the SLK III ensures an effective pressure relief
Improved electrical safety for patients and users through a high-quality EPR power cord
Ground bond test point to execute the VDE- 075 I – I (IEC 62353)
Areas of Application
Decubitus prophylaxis and decubitus therapy up to stage 3 according to EPUAP (European Pressure Ulcer Advisory Panel), considering all factors that influence a patient's condition
Increased blood circulation in the skin and increased venous return (reactive hyperemia)
Technical Specifications
Control Unit: 220 V / 50 Hz
Input: 20 Watt
Measurements Power Unit: 25 x 30 x 13 cm (9.84 "height x 11.81" width x 5.12" depth)
Measurements Overlay: 21 x 90 x 200 cm (8.27" height x 35.43" width x 78.74" length)